您当前的位置: > 详细浏览

Calorimetric Power Measurements in the EAST ECRH System

Calorimetric Power Measurements in the EAST ECRH System

摘要 : In this paper, the calorimetric power measurement method for electron cyclotron resonance heating system on EAST are presented. This method requires measurement of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature is controlled to be stable to get more accurate results. The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. A novel temperature calibration method is proposed also. This kind of calibration method is accurate and effective, and can be easily implemented.

版本历史

[V2] 2017-08-28 10:00:03 ChinaXiv:201703.00011V2 下载全文
[V1] 2017-03-02 20:09:34 ChinaXiv:201703.00011v1 查看此版本 下载全文
点击下载全文
预览
同行评议状态
待评议
许可声明
metrics指标
  •  点击量4394
  •  下载量2150
评论
分享
邀请专家评阅