您当前的位置: > 详细浏览

Improved -defined isochronous mass spectrometry for mass measurements of exotic nuclei

请选择邀稿期刊:
摘要: The technique of -defined isochronous mass spectrometry (-IMS), established at a storage ring, serves as a valuable tool for determining the masses of short-lived nuclei. In the previous -IMS experiments, the effects of magnetic field drifts have to be corrected in order to improve the mass resolving power of -IMS [Eur. Phys. J. A 59, 27 (2023)]. The correction procedures are complicated and require multiple reference ions with well-known masses in each injection, which may not be the cases in the measurements of exotic nuclei with tiny production yields. In this study, we propose a novel approach of -IMS that requires only one reference ion for mass determination in an individual injection, avoiding the tedious and complicated correction procedures. This approach achieves the mass precision comparable to that of previous -IMS results, and is approved to be suitable for future mass measurements of exotic nuclei with extremely low production yields.

版本历史

[V1] 2025-08-11 18:12:23 ChinaXiv:202508.00008V1 下载全文
点击下载全文
预览
同行评议状态
待评议
许可声明
metrics指标
  •  点击量64
  •  下载量10
评论
分享
申请专家评阅