您当前的位置: > 详细浏览

HY-2A Radar Altimeter Ultra Stable Oscillator Drift Estimation using Reconstructive Transponder with its Validation by Multi-mission Cross-Calibration

请选择邀稿期刊:
摘要: The paper presents a method estimating the HY-2A altimeter ultra stable oscillator (USO) drift with a reconstructive transponder. The frequency of the USO of the in-orbit altimeter changes with age, and a bias between the actual frequency and the nominal one exists. The USO bias contributes a portion of the altimeter range drift. The HY-2A altimeter transmits signals at a fixed time interval during calibration, and the actual interval between adjacent altimeter transitions, which is controlled by the USO, is different from the nominal one due to the USO drift. The reconstructive transponder measures the arrival times of the altimeter transmitted signals accurately with the atomic clock. The drift of the USO on-board the HY-2A altimeter can be estimated accurately by using the ranges from the reconstructive transponder and the HY-2A altimeter. The USO drifts of around 40 cm/year are presented. Furthermore, the multi-mission crosscalibration provides preliminary validation of HY-2A altimeter USO drift.

版本历史

[V1] 2016-12-26 16:15:25 ChinaXiv:201612.00205V1 下载全文
点击下载全文
预览
同行评议状态
待评议
许可声明
metrics指标
  •  点击量3654
  •  下载量1564
评论
分享