您当前的位置: > 详细浏览

The research of backscattering effect on the installed area monitors and/or warning devices for gamma radiation

请选择邀稿期刊:
摘要: This paper reports an experimental investigation into the backscatter effects on gamma radiation monitors. The study addresses deviations in measurement readings observed in wall-mounted monitors compared to free-air devices due to backscatter phenomena. Reinforced concrete test blocks were employed to simulate operational environments, with measurements conducted using three detector types: a radiation protection level dosimeter with ionization chamber, an air-kerma radiation monitor with counter tube, and a radiation detector with NaI(Tl) scintillator. Analysis of backscatter factors at varying distances and orientations revealed that: (1) backscatter factors decreased with increasing source-to-surface distance, and (2) central irradiation generally yielded higher backscatter factors than non-central irradiation. The experimental data provide essential reference for formulating or revising pertinent technical standards.

版本历史

[V1] 2025-07-07 15:13:48 ChinaXiv:202507.00132V1 下载全文
点击下载全文
预览
同行评议状态
待评议
许可声明
metrics指标
  •  点击量142
  •  下载量11
评论
分享
申请专家评阅