您当前的位置: > 详细浏览

Equivalent Modeling of Microchannel Plate Framing Camera Gain Uniformity

请选择邀稿期刊:
摘要: In X-ray framing cameras, the gating pulse will be attenuated as it transmits along the microchannel plate (MCP) microstrip cathode, which affects the dynamic gain uniformity of the MCP. A full-wave electromagnetic attenuation model for gating pulse transmission on the MCP microstrip cathode was established to investigate dynamic gain uniformity. To improve computational efficiency, the porous MCP containing on the order of 10^7 microchannels was represented as an equivalent homogeneous medium with a frequency-dependent complex permittivity. For a Gaussian gating pulse with an amplitude of −2 kV and a full width at half maximum (FWHM) of 200 ps propagating along a 40 mm-long and 8 mm-wide microstrip, the simulated pulse decreased to −1.05 kV and the FWHM increased to 240 ps. As a result, the MCP gain decreased to 33% along the pulse transmission direction. An X-ray framing camera has been developed to verify the correctness of the theoretical model. The MCP dynamic gain uniformity was measured using an ultraviolet laser with a FWHM of 6.5 ns, which demonstrated that the gain dropped to 27%, consistent with the simulation result. An error-correction model was proposed, which reduced the normalized root mean square error from 4.72% for the original simulation to 2.58%.